This is the latest recevied telemetry packets stored in our database for station/object N0PRG-1. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | Vbatt* | Vinverter* | VbattTemp* | intTemp* | extTemp* |
---|---|---|---|---|---|
1726792292 | 13.43 Volts | 13.6 Volts | 80 F | 98 F | 82 F |
1726791692 | 13.46 Volts | 13.8 Volts | 80 F | 98 F | 82 F |
1726791092 | 14.05 Volts | 13.8 Volts | 82 F | 98 F | 82 F |
1726790493 | 13.81 Volts | 13.6 Volts | 82 F | 100 F | 82 F |
1726789889 | 14.22 Volts | 13.7 Volts | 84 F | 100 F | 84 F |
1726789289 | 13.66 Volts | 13.6 Volts | 84 F | 100 F | 84 F |
1726788694 | 13.59 Volts | 13.8 Volts | 84 F | 100 F | 84 F |
1726788093 | 13.6 Volts | 13.7 Volts | 84 F | 100 F | 84 F |
1726787491 | 14.09 Volts | 13.9 Volts | 84 F | 100 F | 84 F |
1726786891 | 13.78 Volts | 13.9 Volts | 84 F | 98 F | 84 F |
1726786292 | 13.74 Volts | 13.7 Volts | 82 F | 98 F | 84 F |
1726785692 | 14.2 Volts | 13.7 Volts | 82 F | 98 F | 82 F |
1726785091 | 13.54 Volts | 13.7 Volts | 82 F | 96 F | 82 F |
1726784493 | 14.05 Volts | 13.7 Volts | 82 F | 96 F | 82 F |
1726783890 | 13.6 Volts | 13.6 Volts | 80 F | 96 F | 82 F |
1726783292 | 13.94 Volts | 13.8 Volts | 80 F | 96 F | 82 F |
1726782692 | 13.79 Volts | 13.7 Volts | 80 F | 96 F | 80 F |
1726782091 | 13.51 Volts | 13.9 Volts | 80 F | 96 F | 80 F |
1726781492 | 13.85 Volts | 13.7 Volts | 80 F | 96 F | 80 F |
1726780891 | 13.93 Volts | 13.8 Volts | 80 F | 96 F | 80 F |
1726780292 | 13.59 Volts | 13.7 Volts | 80 F | 96 F | 80 F |
1726779691 | 13.88 Volts | 13.8 Volts | 80 F | 96 F | 80 F |
1726779093 | 13.77 Volts | 13.7 Volts | 80 F | 96 F | 80 F |
1726778490 | 14.17 Volts | 13.8 Volts | 80 F | 96 F | 78 F |
1726777892 | 14.05 Volts | 13.7 Volts | 80 F | 96 F | 78 F |
*Used Equation Coefficients:
Vbatt: 0, 0.01, 0
Vinverter: 0, 0.01, 0
VbattTemp: 0, 1, 0
intTemp: 0, 1, 0
extTemp: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)